Electronic Power Transfer Switch (EPTS) Option for EMC Compliance Testing

Full EMC Compliance Testing of Specific Immunity IEC Standards

The EPTS Option allows EMC Test labs to perform full compliance testing of products to the following IEC standards:
Immunity
IEC 61000-4-11 AC Voltage Dips, Interruptions and Variations to 16A/phase
IEC 61000-4-27 Three Phase
Voltage Unbalance to 16A/phase
IEC 61000-4-34 AC Voltage Dips, Interruptions and Variations to 75A/phase
See the ECTS2 systems product pages for a comprehensive and cost effective solution to all of your EMC compliance testing needs!

Models Table

MODEL

MAX CURRENT

OUTPUT FORM

Voltage Dips and Interruptions Electronic Power Transfer Switch Options
EPTS-16A-1 16 A Single Phase
EPTS-16A-3 16 Arms / phase Three Phase
EPTS-32A-1 32 A Single Phase
EPTS-32A-3 32 A / phase Three Phase
EPTS-75A-1 75 A Single Phase
EPTS-75A-3 75 A / phase Three Phase
EPTS-100A-1 100 A Single Phase
EPTS-100A-3 100 A / phase Three Phase

Key Features

EPTS Option Key Features

  • AC Voltage Dips, Interruptions and Variations
  • Available in Single or Three Phase Three versions
  • Requires second AC Source or AC Line for Nominal Voltage
  • Synchronizes to AC Line and provides sync out to programmable AC source
  • EMC Test Software for AC voltage dips, interruptions and variations
  • Test Files for IEC61000-4-11, -4-27 and -4-34 Included
  • Create and save custom test sequence files using included Windows GUI Software
  • Detailed test reports to documents EUT compliance
  • Wide Range of Current Levels Available
  • Meets required 1 ~ 5 µsec rise/fall time for IEC61000-4-11/34
  • Up to 0-400 VAC L-N / 690V L-L Test Voltage
  • USB Interface
  • AC Bias Input: 120Vac or 230Vac, 50/60Hz

Solutions

IEC 61000-3-2 & IEC 61000-3-12 Harmonics and Inter Harmonics Emissions Test

When combined with ECTS2 Harmonics and Flicker Test System, AFX AC & DC power source or LMX AC Power Source.

AC Voltage Dips, Interruptions, Variations and Unbalance

The EPTS is designed to work with two AC sources, one of which must be programmable. In locations where the grid voltage is stable and has the correct voltage and frequency, the grid can be used for the nominal test voltage. The dips and interruptions levels are always provided by the programmable AC source.

Three Phase AC Voltage Unbalance

The EPTS Windows also supports Voltage Unbalance immunity testing for 3 phase loads per IEC 61000-4-27.

EPTS Option Specifications

Test Voltage Inputs:

AC: 3 Phase + Neutral


Phase Sync (AC Only):

Range: 0.0° ~ 359.9° Accuracy: 0.3°

Test Voltage:

Up to 400Vac Over/Undershoot: < 5% Utest


IEC Modes:

IEC61000-4-11, IEC61000-4-27, IEC61000-4-34

Dimensions and Weights:

2U Models
HxWxD: 89 x 425 x 552 mm
3.5″ x 16.7″ x 20.5″
11.5 Kg / 25.4 lbs
4U Models
HxWxD: 178 x 432 x 670 mm
7″ x 17″ x 26.4″
42.5 Kg / 93.7 lbs

Photos

Electronic Power Transfer

Switch – 4U (EPTS)

Electronic Power Transfer

Switch – 2U (EPTS)

EPTS Graphical User Interface

4 Windows Test Sequence

Screen

Product Brochure:

Download brochure to review product and application notes.