EMI Receivers and Click Analyzer
Narda offers a full range of FULL and PRE compliance receiver, even with FFT technology, covering the range 10 Hz – 18 GHz. As a small size, flexible and reliable, even with built-in LISN, allow you to perform conducted and radiated test in full compliance CISPR 16-1-1 and MIL-STD
9010F
10 Hz – 30 MHz
FFT EMI Receiver
- Advanced analog-to-digital conversion and sophisticated data processing.
- FFT analysis of frequency spectrum for unprecedented precision.
- Full compliance with CISPR 16-1-1 standard.
- Monitoring and analysis of EMI emissions with maximum precision.
- Rapid and accurate identification of disturbance sources.
- Full range of filters and detectors compliant with CISPR and MIL-STD regulations.
- Reliability of measurements and compliance with various EMC test applications.
- Expandable frequency range up to 18 GHz with optional external units.
- Versatile tool suitable for various measurement needs.
Description
Introducing the 9010F, a revolutionary receiver at the forefront of EMI technology. It integrates cutting-edge analog-to-digital conversion and FFT analysis, ensuring precision in EMI measurement as per CISPR standards.
Empowered by real-time data acquisition, the 9010F enables seamless monitoring and analysis of EMI emissions, guaranteeing swift identification of interference sources.
Compliant with CISPR and MIL-STD regulations, the 9010F ensures reliable measurements for diverse EMC test applications, equipped with a range of filters and detectors.
Enhancing its versatility, optional external units extend the frequency range up to 18 GHz.
This flexibility renders the 9010F indispensable for varied measurement needs, from component verification to system analysis.
9030, 9060, 9180
30 MHz – 18 GHz
External units full compliance for 9010F
The 3 available models are:
- 9030 – from 30 MHz to 3 GHz
- 9060 – from 30 MHz to 6 GHz
- 9180 – from 6 GHz to 18 GHz
Description
With the external units 9030, 9060 and 9180 you can easily extend the frequency range of your receiver up to a maximum of 18 GHz.
Light and compact size, these units are equipped with a rechargeable Lio-Ion that allows you to work for hours without any interference.
These external units are fully compliant with CISPR16-1-1 requirements and meet all commercial and military standards for EMC measurements. All external units are fully compatible with the receivers of the 9010 Series, 9010 and 9010F / xxP
CA0010
Click Analyzer
Four-channel Click Analyzer with integrated LISN and full CISPR calibrator
- Cutting-edge technology for maximum accuracy.
- Revolutionary architecture for increased efficiency.
- Flexibility and scalability to meet various needs.
- Comprehensive software for in-depth analysis.
- Reliability and ease of use.
- Conducted and click emission measurements.
- Compliance testing to CISPR standards.
- Analysis of disturbances generated by components such as relays and switches.
- EMC research and development.
Description
The Click Analyzer CA0010, a collaboration between Narda and PMM, exemplifies precision and reliability in click measurement.
Engineered to meet rigorous standards like CISPR 14-1 ed. 7, IEC/EN55014-1, and CISPR 16-1-1.
When paired with Narda FFT EMI Receivers, it ensures compliance with current and future standards, enhancing EMC testing capabilities.
The CA0010 integrates advanced features within its architecture, including a 16A LISN for precise measurements.
Its flexibility extends to compatibility with external PMM LISNs for three-phase loads up to 500A.
Software packages, PCA and PCG, enable detailed analysis and streamline CISPR test sequences.
Reliable and user-friendly, the CA0010 requires no IT components and simplifies click measurements for all operators.
In conclusion, the CA0010 is essential for accurate and reliable click measurements in EMC laboratories.
ER8000
9 kHz – 3 GHz with LISN
FFT EMI Receiver with LISN
- Compliant with CISPR 16-1-1, MIL-STD-461, ANSI C63.2 and FCC
- Compliant with CISPR 14-1 when in conjunction with CA0010
- Conducted and radiated emission tests
- Direct analog to digital conversion up to 30 MHz
- Combination of EMI test receiver and spectrum analyzer
- Operates gapless FFT
- Very fast measuring time
- Built-in Lines Impedance Stabilization Networks (LISN)
- User port for driving external LISNs and ancillaries
- Free PES PMM Emission Suite Software
- Robust, compact construction
- 140 dBμV (2 W) maximum input level without damage
Description
The Compact and Powerful EMI Receiver for Fast and Accurate Measurements
Flexibility and ease of use:
The ER8000 receiver stands out for its exceptional compactness, making it ideal for use in tight spaces. Despite its compact size, it offers exceptional flexibility and ease of use, making it accessible even to less experienced users.
High performance and regulatory compliance:
The high performance of the ER8000 makes it the ideal tool for the precise measurement of conducted and radiated emissions. Full compliance with CISPR 16-1-1 ensures maximum reliability of the results obtained.
Unprecedented measurement speed:
Thanks to its state-of-the-art FFT architecture, the ER8000 boasts exceptionally fast analysis times: just 2 seconds in band B and 1 minute in bands C+D. This feature allows you to optimize the measurement process and increase productivity.
Efficient front-end and versatile interface:
The ER8000’s front-end features an efficient preselector that guarantees exceptional performance in terms of sensitivity and selectivity. The intuitive user interface and USB port for controlling external devices such as LISNs and switching boxes complete the equipment of this versatile instrument.
Applications in design and certification:
The ER8000 is the ideal tool for performing emission measurement tests and characterizing EUTs (Equipment Under Test) quickly and efficiently. Its flexibility makes it suitable for use both in the design laboratory during product development and in an EMC laboratory for the certification of EMI measurements.
Two frequency ranges for different needs:
The ER8000 is available in two different frequency ranges:
- 9 kHz to 30 MHz (ER8000 option 00)
- 9 kHz to 3 GHz (ER8000 option 01)
Users can also upgrade from option 00 to option 01 at any time, ensuring maximum flexibility and scalability to meet specific needs.
ER9000
10 Hz – 3 GHz
FFT EMI Receiver
- ER9000 Opt. 00: 10 Hz – 30 MHz
- ER9000 Opt. 01: 10 Hz – 3 GHz
- Very fast FFT scan gapless (2 sec. In Band B, 1 min. In Band C + D)
- Color Touch-Screen Display
- Compliant with CISPR 16-1-1, MIL-STD-461, ANSI C63.2 and FCC
- Compliant with CISPR 14-1 in combination with the Click CA0010 extension
- Lightning-fast full-compliant scanning
- Integrated CISPR pulse generator
- Robust and compact construction, battery operated and with AC / DC power supply
- Free PES (PMM Emission Suite) software with advanced EMC functionality
Description
The New Standard for Electromagnetic Emission Measurement
Innovative design for maximum efficiency:
The latest addition to the PMM receiver family, the ER9000, stands out for its avant-garde design that combines practicality and robustness. The practical and intuitive color touch-screen display offers a user-friendly interface, while the compact and robust chassis makes it extremely easy to handle.
Perfect for laboratory and field use:
Thanks to its portability and the included Li-Ion battery, the ER9000 is ideal for both laboratory and “in-field” use. Whether it’s routine testing in an EMC certification lab or on-site analysis, the ER9000 is the perfect tool for accurate electromagnetic emission measurement.
Unprecedented speed and accuracy:
The extremely fast scan time, in full compliance with the CISPR 16-1-1 standard, is guaranteed by an even more refined FFT technology. The ER9000 offers exceptional performance in terms of speed and accuracy, allowing you to optimize the measurement process and obtain reliable results.
A benchmark in EMI technology:
The ER9000 represents a new benchmark among EMI receivers. The modular design, typical of PMM products, allows you to extend the frequency range and add advanced measurement features, such as click analysis.
FR-4003
9 kHz – 30 MHz
FFT field receiver and ROD antenna
Main features of FR-4003:
- Antenna CISPR 12, CISPR 16, CISPR 25, MIL-STD, DO-160 fully compliant
- Internal full CISPR 16-1-1 receiver
- Operates both swept and gapless FFT modes
- Very fast measuring time
- Embedded attenuator, preamplifier and preselectors
- Fiber optic serial link to 9010F series or directly to PC
- Grounding effectiveness auto-diagnostic capability
- On-board tracking generator and antenna CISPR adapter
- Automatic diagnostic and calibration
- Scattering free
- PC software
- RF front-end output
- On-board capacitance meter
- Plug-in rechargeable Li-ion battery
Description
The FR4003 improves electric field measurement. It surpasses traditional rod antennas. It meets MIL-STD and CISPR specifications. It functions as a CISPR 16-1-1 receiver. It operates alone or with a PMM receiver. It meets standards in swept and FFT modes. It has analog signal output. Caution advised due to scattering. Internal receiver has preselectors, attenuators. Control via firmware or manual operation. Includes a tracking generator. Facilitates self-calibration and accuracy. Verifies grounding effectiveness. Functions as a field generator. Broadcasts internally generated signals. Includes controlling software. Operates on rechargeable Li-ion battery. Provides uninterrupted operation for several hours. Ensures measurements in undisturbed field.
Series 9010/XXP
10 Hz – 6 GHz
Full/Pre compliance receivers
Receivers 9010/xxp are available in the following versions:
- 9010/03P, 10 Hz – 300 MHz
- 9010/30P, 10 Hz – 3 GHz
- 9010/60P, 10 Hz – 6 GHz
Description
Narda-PMM has developed new EMI / EMC receivers based on an innovative concept and a revolutionary approach to meet the needs of small and medium-sized laboratories that do not find it convenient to invest in a receiver conforming to the CISPR 16-1-1 also for radiated measurements.
They are a perfect mix of full and Pre-Compliance to meet, in a perfect way, the requirements of practical tests, not excluding the possibility of future upgrades to 100% Full-Compliant to CISPR 16-1-1 up to 3, 6 or 18 GHz the simple addition of an external unit, 9030, 9060 or 9180, connected via fiber optic cable.
The 9010 / xxP series receivers, are full compliance in accordance with the CISPR 16-1-1 in the band A and B and pre compliance in the next