Product overview

RIS-6091 is the first set of mature multifunctional radiofrequency conducted immunity test system developed by LIONCEL.

Feature:

  1. Upper computer control, standard Chinese and English professional test software, complete function and good scalability.
  2. all kinds of coupling decoupling networks are complete to meet the needs of different test ports.
  3. System frequency range: 150kHz~230MHz;
  4. Built-in signal source frequency range: 9kHz~1GHz;
  5. Built-in power amplifier frequency range: 150kHz~230MHz, 35W or 85W, linear power indicators.
  6. Built-in power meter: 9kHz~3GHz;
  7. Automatic calibration, fully automatic test and output power monitoring function;
  8. Externally scalable testing. Both software and hardware support high-current injection, direct injection and closed-loop testing.

Meet the standards:

IEC61000-4-6    

ISO11452-4

Technical Parameter:

Type

 

RIS-6091

Output voltage

35W power amplifier

1~17Vrms(with CDN)

1~11Vrms(with EM Clamp)

85W power amplifier

1~30Vrms(with CDN)

1~18Vrms(with EM Clamp)

1~10Vrms(with current Clamp)

Output impedance

50Ω

VSWR

≤1.2

Signal-source

Frequency

9k~1GHz(Can extend to max. 3GHz)

Output level

-60~10dBm

Un-modulated signal

Continuous-wave (CW)

Modulation mode

Amplitude-modulation    

Frequency:1Hz~10kHz

Depth:1~99%

Pulse-modulation    

Frequency:1Hz~1kHz

Duty cycle:  1~100%

Power amplifier

Output frequency

150kHz~230MHz(Can extend to 10kHz400MHz)

MAX output power

+44dBm/35W(Can extend to +49dBm/85W)

Harmonic

<15dBc

3x Power meters

(1x Forward Power, 1x Reverse Power, 1x Monitoring Level)

Input frequency

9kHz~3GHz

Input power

-40dBm~+30dBm

System configuration

Software

Support Windows 

Control port

USB

Output port

N-connector

Size

19”/4U

Measurement Software


CDN-M series, CDN-T series, CDN-S series, CDN-AF series

Product overview

 

Feature:

1.All kinds of coupling decoupling networks have various specifications, according to the needs of various test ports.

2.150kHz~230MHz full-band impedance meets the standard requirements.

3.Adapt to all kinds of brand RF immunity test system.

Coupled-decoupled network types model Test port Voltage/Current
Power Line CDN-M1-16/32 Single-phase single-wire power line 220 V/16 A (32 A)
CDN-M1-100 Single-phase single-wire power line 220 V/100 A
CDN-M1-200 Single-phase single-wire power line 220 V/200 A
CDN-M2-16/32 Single-phase two-wire power cord 220 V/16 A (32 A)
CDN-M2-100 Single-phase two-wire power cord 220 V/100 A
CDN-M2-200 Single-phase two-wire power cord 220 V/200 A
CDN-M3-16/32 Single-phase three-wire power cord 220 V/16 A (32 A)
CDN-M3-32-3 Three-phase three-wire power supply 380 V/32 A
CDN-M3-100 Three-phase three-wire power supply 690 V/100 A
CDN-M3-200 Three-phase three-wire power supply 690 V/200 A
CDN-M4-32 Three-phase four-wire power supply 380 V/32 A
CDN-M4-32-PE Three-phase four-wire power supply 380 V/32 A
CDN-M4-200 Three-phase four-wire power supply 690 V/200 A
CDN-M5-32 Three-phase five-wire power supply 380 V/32 A
CDN-M5-100 Three-phase five-wire power supply 690 V/100 A
CDN-M5-200 Three-phase five-wire power supply 690 V/200 A
Unshielded symmetry lines CDN-T2 2 lines 100 V/5 A
CDN-T4 4 lines 100 V/5 A
CDN-T8 8 lines 100 V/5 A
Unshielded asymmetric lines CDN-AF2 2 lines 100 V/5 A
CDN-AF4 4 lines 100 V/5 A
CDN-AF8 8 lines 100 V/5 A
Shielded wire CDN-S8 8 lines 100 V/5 A
CDN-S10 10 cores and 6 wires 100 V/5 A

EM Injection Clamp

Specification

EMIC-681

Test Parameters

Frequency Range

10 kHz to 1000 MHz

Impedance

50 Ω

Connector

N-type(female)

 

Maximum Input Power

10 kHz to 100 MHz,CW 100 W,for 15 minute

100 MHz to 230 MHz,CW 100 W,for 10 minute

230 MHz to 1 GHz,CW 50 W,for 10 minute

Maximum Inner Diameter

23 mm

Maximum Test Voltage

45 V

General Parameter

Dimension

610.0 mm×80.0 mm×135.0 mm

Weight

5 kg

Calibration Fixture, included

EMCL-C