Product overview
Feature:
- Upper computer control, standard Chinese and English professional test software, complete function and good scalability.
- all kinds of coupling decoupling networks are complete to meet the needs of different test ports.
- System frequency range: 150kHz~230MHz;
- Built-in signal source frequency range: 9kHz~1GHz;
- Built-in power amplifier frequency range: 150kHz~230MHz, 35W or 85W, linear power indicators.
- Built-in power meter: 9kHz~3GHz;
- Automatic calibration, fully automatic test and output power monitoring function;
- Externally scalable testing. Both software and hardware support high-current injection, direct injection and closed-loop testing.
Meet the standards:
IEC61000-4-6
ISO11452-4
Technical Parameter:
Type |
RIS-6091 |
|
|
Output voltage |
35W power amplifier |
1~17Vrms(with CDN) 1~11Vrms(with EM Clamp) |
|
85W power amplifier |
1~30Vrms(with CDN) 1~18Vrms(with EM Clamp) 1~10Vrms(with current Clamp) |
|
|
Output impedance |
50Ω |
|
|
VSWR |
≤1.2 |
|
Signal-source |
||
|
Frequency |
9k~1GHz(Can extend to max. 3GHz) |
|
|
Output level |
-60~10dBm |
|
|
Un-modulated signal |
Continuous-wave (CW) |
|
|
Modulation mode |
Amplitude-modulation Frequency:1Hz~10kHz Depth:1~99% Pulse-modulation Frequency:1Hz~1kHz Duty cycle: 1~100% |
|
Power amplifier |
||
|
Output frequency |
150kHz~230MHz(Can extend to 10kHz400MHz) |
|
|
MAX output power |
+44dBm/35W(Can extend to +49dBm/85W) |
|
|
Harmonic |
<15dBc |
|
3x Power meters(1x Forward Power, 1x Reverse Power, 1x Monitoring Level) |
||
|
Input frequency |
9kHz~3GHz |
|
|
Input power |
-40dBm~+30dBm |
|
System configuration |
||
|
Software |
Support Windows |
|
|
Control port |
USB |
|
|
Output port |
N-connector |
|
|
Size |
19”/4U |
|

Measurement Software
CDN-M series, CDN-T series, CDN-S series, CDN-AF series
Product overview

Feature:
1.All kinds of coupling decoupling networks have various specifications, according to the needs of various test ports.
2.150kHz~230MHz full-band impedance meets the standard requirements.
3.Adapt to all kinds of brand RF immunity test system.
| Coupled-decoupled network types | model | Test port | Voltage/Current |
| Power Line | CDN-M1-16/32 | Single-phase single-wire power line | 220 V/16 A (32 A) |
| CDN-M1-100 | Single-phase single-wire power line | 220 V/100 A | |
| CDN-M1-200 | Single-phase single-wire power line | 220 V/200 A | |
| CDN-M2-16/32 | Single-phase two-wire power cord | 220 V/16 A (32 A) | |
| CDN-M2-100 | Single-phase two-wire power cord | 220 V/100 A | |
| CDN-M2-200 | Single-phase two-wire power cord | 220 V/200 A | |
| CDN-M3-16/32 | Single-phase three-wire power cord | 220 V/16 A (32 A) | |
| CDN-M3-32-3 | Three-phase three-wire power supply | 380 V/32 A | |
| CDN-M3-100 | Three-phase three-wire power supply | 690 V/100 A | |
| CDN-M3-200 | Three-phase three-wire power supply | 690 V/200 A | |
| CDN-M4-32 | Three-phase four-wire power supply | 380 V/32 A | |
| CDN-M4-32-PE | Three-phase four-wire power supply | 380 V/32 A | |
| CDN-M4-200 | Three-phase four-wire power supply | 690 V/200 A | |
| CDN-M5-32 | Three-phase five-wire power supply | 380 V/32 A | |
| CDN-M5-100 | Three-phase five-wire power supply | 690 V/100 A | |
| CDN-M5-200 | Three-phase five-wire power supply | 690 V/200 A | |
| Unshielded symmetry lines | CDN-T2 | 2 lines | 100 V/5 A |
| CDN-T4 | 4 lines | 100 V/5 A | |
| CDN-T8 | 8 lines | 100 V/5 A | |
| Unshielded asymmetric lines | CDN-AF2 | 2 lines | 100 V/5 A |
| CDN-AF4 | 4 lines | 100 V/5 A | |
| CDN-AF8 | 8 lines | 100 V/5 A | |
| Shielded wire | CDN-S8 | 8 lines | 100 V/5 A |
| CDN-S10 | 10 cores and 6 wires | 100 V/5 A |
EM Injection Clamp

|
Specification |
EMIC-681 |
|
Test Parameters |
|
|
Frequency Range |
10 kHz to 1000 MHz |
|
Impedance |
50 Ω |
|
Connector |
N-type(female) |
|
Maximum Input Power |
10 kHz to 100 MHz,CW 100 W,for 15 minute 100 MHz to 230 MHz,CW 100 W,for 10 minute 230 MHz to 1 GHz,CW 50 W,for 10 minute |
|
Maximum Inner Diameter |
23 mm |
|
Maximum Test Voltage |
45 V |
|
General Parameter |
|
|
Dimension |
610.0 mm×80.0 mm×135.0 mm |
|
Weight |
5 kg |
|
Calibration Fixture, included |